Search results for "Active volume"

showing 2 items of 2 documents

Description and commissioning of NEXT-MM prototype: first results from operation in a Xenon-Trimethylamine gas mixture

2014

[EN] A technical description of NEXT-MM and its commissioning and first performance is reported. Having an active volume of ∼35 cm drift × 28 cm diameter, it constitutes the largest Micromegas-read TPC operated in Xenon ever constructed, made by a sectorial arrangement of the 4 largest single wafers manufactured with the Microbulk technique to date. It is equipped with a suitably pixelized readout and with a sufficiently large sensitive volume (∼23 l) so as to contain long (∼20 cm) electron tracks. First results obtained at 1 bar for Xenon and Trymethylamine (Xe-(2%)TMA) mixture are presented. The TPC can accurately reconstruct extended background tracks. An encouraging fu…

Enginyeria -- InstrumentsMECANICA DE LOS MEDIOS CONTINUOS Y TEORIA DE ESTRUCTURASMaterials sciencePhysics - Instrumentation and DetectorsTime projection chambersParticle tracking detectors (Gaseous detectors)chemistry.chemical_elementTrimethylamineFOS: Physical sciencesElectron7. Clean energyEngineering instrumentsTECNOLOGIA ELECTRONICAchemistry.chemical_compoundXenonOpticsWafer[PHYS.PHYS.PHYS-INS-DET]Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det]InstrumentationMathematical PhysicsDetectors de radiacióTime projection chamberbusiness.industryActive volumeMicroMegas detectorInstrumentation and Detectors (physics.ins-det)Double-beta decay detectorschemistryVolume (thermodynamics)Nuclear countersFísica nuclearbusiness
researchProduct

Calibration campaign of the Borexino detector for the search of sterile neutrinos with SOX

2020

Abstract The SOX (Short distance Oscillations with boreXino) experiment aims to investigate possible anomalous oscillatory behaviours in neutrinos, including the existence of sterile neutrinos, by exploiting the very low radioactive background of the Borexino detector. A calibration campaign is crucial to achieve a deeper understanding of the energy response and the spatial reconstruction accuracies of the detector. It will be performed with a suite of low-activity radioactive sources which will map the whole active volume, especially nearby the inner vessel. The calibration points at the border of the active zones will be extremely important to study the neutron detection efficiency. The c…

PhysicsHistorySterile neutrinoPhysics::Instrumentation and DetectorsCalibration (statistics)Active volumeDetectorComputer Science ApplicationsEducationShort distanceNeutron detectionNeutrinoBorexinoRemote sensingJournal of Physics: Conference Series
researchProduct